HART Temperature Transmitter

Industry-leading temperature transmitter delivers unmatched field reliability and
innovative process measurement solutions:
• measures process temperature in monitoring applications without the requirement of
a thermowell or process penetration
• Superior accuracy and stability
• Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
• Comprehensive sensor and process diagnostics offering
• IEC 61508 safety certification
• Dual-compartment housing
• Large LCD display
• Selectable HART®
Improve efficiency with Best-in-Class product specifications and capabilities:
• Reduce maintenance and improve performance with industry leading accuracy and
stability.
• Improve measurement accuracy by 75 percent with Transmitter-Sensor Matching.
• Ensure process health with system alerts and easy-to-use Device Dashboards.

Technical Specification

 

Dimensions                                                                                                     Ø 110 mm
Dimensions (HxWxD), aluminum                                                       109.3 x 145 x 126 mm
Supply voltage, DC: Ex ia, intrinsically safe                                   10 (12 – with backlight) …30 VDC
Supply voltage, DC: Other                                                                     10 (12 – with backlight) …35 VDC
Isolation voltage, test / working                                                          1.5 kVAC / 50 VAC
Response time (programmable)                                                          1…60 s
Signal / noise ratio                                                                                       > 60 dB
Programming                                                                                                 HART
Start-up time, transmitter to display Max.                                     5 s
Long-term stability                                                                                     Better than ±0.1% of span / year
Transmitter Accuracy                                                                                Better than 0.05% of selected range
RTD type                                                                                                          Pt50/100/200/500/1000; Ni50/100/120/1000
Output Signal range                                                                                   4…20 mA
Min. signal range                                                                                          16 mA
HART protocol revisions                                                                          HART 7 and HART 5

 

For More Products check out our catalogue